Modular timing relay, Harmony, 8A, 1 CO, 0.05s…300h, on delay, 24...240V AC DC

Produttore:
Schneider Electric
Schneider%20electric

016ae1f6eebb8bab61d1f2f3536077395a726285 medium
Prezzo (IVA esclusa)
€ 74.13
Codice Nuova Elva
RE22R1MAMR
Codice produttore
RE22R1MAMR
Disponibilità
Invia RdO

This Harmony RE22 timing relay can be set between 0.5mm wide and can be supplied with 24V to 240V AC. This modular timing relay is ideal for providing timing control in automation systems such as automatic door opening, alarm, lighting in toilets and car park barriers. It also offers a sealable cover, simple and precise settings with rotary trimmers. Status display with 2 LEDs, visually inspect the status of you system without specialized tools. Diagnostic button allows simple setup and trouble shooting by non-specialists. 0 0 0 0 0 0 0 0 0 0 0 0 0 0

Specifications

CertificationsCCC
Input Voltage2.4 V
Net Weight0.1 kg
StandardIEC 61812-1
Storage Temperature-40-70 °C
Width22.5 mm

Specifications

Discrete Output Typerelay
Range Of ProductHarmony Timer Relays
Product Or Component Typemultifunction relay
Nominal Output Current8 A
Device Short NameRE22

Complementary

Power Consumption In W1.5 W 240 V DC
Power Consumption In Va3-3 VA 240 V AC
Switching Capacity In Va2000 VA
Minimum Pulse Duration100 ms with load in parallel || 30 ms
Maximum Switching Current8 A
Voltage Range0.85...1.1 Us
Net Weight0.1 kg
Mounting Positionany position
Voltage Drift+/- 0.2 %/V
Reset Time120 ms on de-energisation
Maximum Switching Voltage250 V AC
Safety Reliability DataB10d = 190000 || MTTFd = 205.4 years
Connections - Terminalsscrew terminals, 1 x 0.5...1 x 3.3 mm² AWG 20...AWG 12) solid without cable end || screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end || screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 14) flexible with cable end || screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) flexible with cable end
[Us] Rated Supply Voltage24...240 V AC/DC 50/60 Hz
Temperature Drift+/- 0.05 %/°C
Time Delay Range3...30 h || 0.05...1 s || 30...300 s || 3...30 min || 3...30 s || 30...300 h || 30...300 min || 0.3...3 s || 10...100 s || 1...10 s
Minimum Switching Current10 mA 5 V DC
Overvoltage CategoryIII IEC 60664-1
Input Voltage<= 2.4 V
Mounting Support35 mm DIN rail conforming to EN/IEC 60715
Electrical Durability100000 cycles, 8 A at 250 V, AC-1 || 100000 cycles, 2 A at 24 V, DC-1
Mechanical Durability10000000 cycles
Contacts Type And Composition1 C/O timed contact, cadmium free
Housing Materialself-extinguishing
Status LedGreen LED backlight steady)dial pointer indication || Yellow LED steady)output relay energised || Yellow LED fast flashing)timing in progress and output relay de-energised || Yellow LED slow flashing)timing in progress and output relay energised
[Uimp] Rated Impulse Withstand Voltage5 kV 1.2-50 µs IEC 60664-1
Width22.5 mm
Time Delay Typepower on-delay
Tightening Torque0.6-1 N.m IEC 60947-1
Supply Frequency50...60 Hz +/- 5 %
Repeat Accuracy+/- 0.5 % IEC 61812-1
Setting Accuracy Of Time Delay+/- 10 % of full scale 25 °C IEC 61812-1
Creepage Distance4 kV/3 IEC 60664-1
Maximum Delay Response100 ms
Control Typerotary knob || diagnostic button || potentiometer external
Insulation Resistance100 MOhm 500 V DC IEC 60664-1
Immunity To Microbreaks10 ms

Offer Sustainability

Rohs Exemption InformationYes
Mercury FreeYes
Environmental DisclosureENVPEP1401008EN
Sustainable Offer StatusGreen Premium product
Reach RegulationReference contains Substances of Very High Concern above the threshold
California Proposition 65WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
China Rohs RegulationX
Circularity ProfileENVEOLI1401008EN
Eu Rohs DirectivePro-active compliance (Product out of EU RoHS legal scope)

Environment

Product CertificationsEAC || CSA || RCM || UL || GL || CE || CCC
Ambient Air Temperature For Storage-40-70 °C
Relative Humidity95-95 % 25-55 °C
Ip Degree Of Protectionhousing IP40 IEC 60529 || front face IP50 IEC 60529 || terminals IP20 IEC 60529
Ambient Air Temperature For Operation-20-60 °C
StandardsUL 508 || IEC 61812-1
Electromagnetic Compatibilityfast transients immunity test 1 kV capacitive connecting clip)level 3 IEC 61000-4-4 || surge immunity test 1 kV differential mode)level 3 IEC 61000-4-5 || surge immunity test 2 kV common mode)level 3 IEC 61000-4-5 || electrostatic discharge 6 kV contact discharge)level 3 IEC 61000-4-2 || electrostatic discharge 8 kV air discharge)level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test 10 V/m 80 MHz...1 GHz)level 3 IEC 61000-4-3 || conducted RF disturbances 10 V 0.15...80 MHz)level 3 IEC 61000-4-6 || fast transient bursts 2 kV direct contact)level 3 IEC 61000-4-4 || immunity to microbreaks and voltage drops 30 % 500 ms) IEC 61000-4-11 || immunity to microbreaks and voltage drops 100 % 20 ms) IEC 61000-4-11
Dielectric Strength2.5 kV 1 mA/1 minute 50 Hz between relay output and power supply basic insulation IEC 61812-1
Shock Resistance15 gn not operating 11 ms IEC 60068-2-27 || 5 gn in operation 11 ms IEC 60068-2-27
Vibration Resistance20 m/s² 10-150 Hz)IEC 60068-2-6
Pollution Degree3 IEC 60664-1
Directives2006/95/EC - low voltage directive || 2004/108/EC - electromagnetic compatibility

Documentazione


Altri articoli da Schneider Electric

Richiedi un preventivo