Limit switch, L100/300, 600 V 10amp type l +options

Produttore:
Schneider Electric
Schneider%20electric

C3864b250bf6eaf92d3adbe675a1832d3b4bbe48 medium
Prezzo (IVA esclusa)
€ 342.24
Codice Nuova Elva
L100WNS2M26
Codice produttore
L100WNS2M26
Disponibilità
Invia RdO

This product is part of the NEMA Limit Switches range, an offer of limit switches. The limit switch is a device that converts a mechanical motion into an electrical control signal. It has 2 normally open and 2 normally closed, DPDT-DB (double pole, double throw, double break) form Zb, snap action contacts. It is a limit switch with a conventional enclosed thermal current of 20A. It is furnished with screw clamp terminals for electrical connection. Limit switch has one 1/2 inch 14 NPT conduit entry. The spring return mechanism without operating lever supports lateral approach and switch actuation in CCW position, from right. It is an IP67 and NEMA 1/2/4/12/13 rated product. This rotary head limit switch has a fixed type body which is made of cast aluminum with corrosion resistant grey painted finish. Its dimensions are 2.25inch (Width) x 3.41inch (Depth) x 4.95inch (Height) and weighs 1.5lb. This limit switch is suitable for material working, packaging, materials handling, conveying, food and beverage, oil, gas, crane, hoisting, mill, foundry, mining and mineral construction. The L100/300 mill and foundry for severe duty fixed sequences 59mm housing, available in 2-pole or 3-pole configurations. This switch is for use in foundries or mills where falling foundry sand or similar material could build up and jam the operating mechanism.

Specifications

Contact Material90/10 AgCdO On Copper Backing Stationary Contact
Depth3.41 in
Height4.95-4.95 in
Net Weight1.5 lbs
Number of Poles2
Storage Temperature-10-185 °F
Warranty Length18 months
Width2.25 in

Specifications

Series Namesevere duty mill
Sale Per Indivisible Quantity1
Body Typefixed
Range Of ProductL100/300
Product Specific Applicationmill switch
Product Or Component Typelimit switch
Device Short NameL100 || L300
Head Typerotary head

Contractual warranty

Warranty18 months

Complementary

Switch ActuationCW and CCW || from left or right
[Ui] Rated Insulation Voltage600 V 3)IEC 60947-1 || 600 V 3)UL 508 || 600 V 3)CSA C22.2 No 14
Positive Openingwithout
Tripping Angle9 °
Cable Entry1 entry for 1/2" - 14 NPT ANSI B1.20.1
Cw Operation Contacts1 NC + 1 NO
Contacts StyleD
Repeat Accuracy+/- 0.03 %
Contact Operationsnap action
Short-Circuit Protection20 A Bussmann class CC KTK-R-20 non-time delay
Contacts Material90/10 AgCdO on copper backing stationary contact || silver on steel backing moveable contact
Maximum Displacement Angle70 °
Fixing Modeby the body
Maximum Actuation Speed90 ft/min with 45° cam angle, levers only || 130 ft/min with 30° cam angle, levers only
Type Of Operatorspring return without operating lever
Body Materialcast aluminium
[Ithe] Conventional Enclosed Thermal Current20 A
Contact FormForm XX
Ccw Operation Contacts1 NC + 1 NO
Switch FunctionDPST-NO-DB
Electrical Connectionscrew-clamp terminals AWG 22...AWG 12
[Uimp] Rated Impulse Withstand Voltage2.5 kV AC for 1 minute CE || 2.2 kV AC for 1 minute UL || 2.64 kV AC for 1 minute CSA
Contact Code DesignationA600, AC (Ue = 600 V) Ie = 5 A NEMA rating designation || A600, AC (Ue = 480 V) Ie = 6.25 A NEMA rating designation || A600, AC (Ue = 240 V) Ie = 12.5 A NEMA rating designation || A600, AC (Ue = 120 V) Ie = 20 A NEMA rating designation || P600, DC (Ue = 600 V) Ie = 0.2 A NEMA rating designation || P600, DC (Ue = 250 V) Ie = 1 A NEMA rating designation || P600, DC (Ue = 120 V) Ie = 5 A NEMA rating designation
Width2.25 in
Depth3.41 in
Minimum Torque For Tripping170 ozf.in
Net Weight1.5 lb(US)
Number Of Poles2
Contact Sequence Number26
Function Availableneutral position
Contacts Type And Composition2 NO
Height4.95-4.95 in
Base Plate Stylestyle 2
Terminals Description Iso N°1(3-4) right side contact || (1-2) left side contact
Type Of Approachlateral approach

Offer Sustainability

Environmental DisclosureENVPEP111160EN
Eu Rohs DirectiveNot applicable, out of EU RoHS legal scope
Reach RegulationReference contains Substances of Very High Concern above the threshold
California Proposition 65WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

Environment

Ambient Air Temperature For Operation-10-185 °F
Ambient Air Temperature For Storage-10-185 °F
Nema Degree Of ProtectionNEMA 1 Nema type 250 || NEMA 2 Nema type 250 || NEMA 4 Nema type 250 || NEMA 12 Nema type 250 || NEMA 13 Nema type 250
Electrical Shock Protection Classclass 0 IEC 61140
Shock Resistance30 gn 9 ms IEC 60068-2-27
Vibration Resistance10 gn 10-55 Hz)IEC 60068-2-6
Protective Treatmentcorrosion resistant gray paint
Ip Degree Of ProtectionIP67 conforming to IEC 60529

Documentazione


Altri articoli da Schneider Electric

Richiedi un preventivo