FO converters - PSI-MOS-PROFIB/FO 850 E - 2708274

Produttore:
PHOENIX CONTACT
Phoenix%20contact

A5e0c2cc56401bc6d40716dd3e953455cb3183b8 medium
Prezzo (IVA esclusa)
€ 1050.76
Codice Nuova Elva
2708274
Codice produttore
2708274
Disponibilità
Invia RdO

FO converter with integrated optical diagnostics, alarm contact, for PROFIBUS up to 12 Mbps, terminal device with one FO interface (BFOC), 850 nm, for PCF/fiberglass cable (multimode)

Features

  • Connections can be plugged in using a COMBICON screw terminal block

  • Can be combined with the PSI copper repeater in a modular way using DIN rail connectors

  • Supply voltage and data signals routed through via DIN rail connectors

  • Automatic data rate detection or fixed data rate setting via DIP switches

  • High-quality electrical isolation between all interfaces (PROFIBUS // fiber optic ports // power supply // DIN rail connector)

  • Redundant power supply possible by means of optional system power supply unit

  • Approved for use in zone 2

  • Integrated optical diagnostics for continuous monitoring of fiber optic paths

  • Intrinsically safe fiber optic interface (Ex op is) for direct connection to devices in zone 1

  • Floating switch contact for leading alarm generation in relation to critical fiber optic paths

  • Suitable for all data rates up to 12 Mbps

  • Bit retiming for any cascading depth

  • Shipbuilding approval in accordance with DNV GL

  • cULus Listed

  • EAC

  • cULus Recognized

  • DNV GL

  • UL Listed

  • cUL Listed

  • UL Recognized

  • cUL Recognized

Specifications

Depth106 mm
Height99 mm
Width35 mm

Conformance/approvals

DesignationCE
IdentificationCE-compliant
DesignationEAC
IdentificationEAC
IdentificationII 3 G Ex nA nC IIC T4 Gc X
Additional textPlease follow the special installation instructions in the documentation!
DesignationATEX
IdentificationII (2) G [Ex op is Gb] IIC
IdentificationII (2) D [Ex op is Db] IIIC
CertificatePTB 06 ATEX 2042 U
DesignationUL, USA/Canada
IdentificationClass I, Zone 2, AEx nc IIC T5
IdentificationClass I, Zone 2, Ex nC nL IIC T5 X
IdentificationClass I, Div. 2, Groups A, B, C, D
DesignationPTB
DesignationPROFIBUS approval
Additional textPROFIBUS-Center Netherlands
DesignationCorrosive gas test
IdentificationISA-S71.04-1985 G3 Harsh Group A
DesignationShipbuilding
IdentificationDNV GL
TemperatureB
HumidityA
VibrationA
EMCB
EnclosureRequired protection according to the Rules shall be provided upon installation on board

Interfaces

Interface 1PROFIBUS acc. to IEC 61158, RS-485 2-wire, half duplex, automatic control
InterfacePROFIBUS
Operating modeSemi-duplex
Connection methodD-SUB-9 female connector
File format/codingUART (11 Bit, NRZ)
Data direction switchingAutomatic control
Transmission mediumCopper
Transmission length≤ 1200 m (depending on the data rate, with shielded, twisted pair data cable)
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.14
Serial transmission speed≤ 12 Mbps

Ambient conditions

Noise immunityEN 61000-6-2:2005
Ambient temperature (operation)-20 °C - 60 °C
Ambient temperature (storage/transport)-40 °C - 85 °C
Permissible humidity (operation)30 % - 95 % (non-condensing)
Altitude≤ 5000 m (For restrictions, see the manufacturer's declaration for altitude operation)
Degree of protectionIP20

Optical interface FO

No. of channels1
Transmit capacity, minimum-4.2 dBm (200/230 µm)
Transmit capacity, minimum-17.8 dBm (50/125 µm)
Transmit capacity, minimum-14.6 dBm (62,5/125 µm)
Minimum receiver sensitivity-30 dBm (50/125 µm)
Overrange receiver-3 dBm (200/230 µm)
Wavelength850 nm
Transmission length incl. 3 dB system reserve2600 m (with F-G 50/125 2.5 dB/km)
Transmission length incl. 3 dB system reserve3300 m (with F-G 62,5/125 3.0 dB/km)
Transmission length incl. 3 dB system reserve800 m (With F-K 200/230 10 dB/km with quick mounting connector)
Transmission mediumPCF fiber
Transmission mediumMulti-mode fiberglass
Transmission protocolProtocol-transparent to the RS-485 interface
Connection methodB-FOC (ST®)

Environmental Product Compliance

REACh SVHCLead 7439-92-1
China RoHSEnvironmentally Friendly Use Period = 50 years
China RoHSFor details about hazardous substances go to tab 'Downloads', Category 'Manufacturer's declaration'

Standards and Regulations

Noise immunityEN 61000-6-2:2005
Free from substances that could impair the application of coatingaccording to P-VW 3.10.7 57 65 0 VW-AUDI-Seat central standard
Connection in acc. with standardCUL
Standards/regulationsEN 61000-4-2
Contact discharge± 6 kV
Standards/regulationsEN 61000-4-3
Standards/regulationsEN 61000-4-4
CommentsCriterion B
Standards/regulationsEN 61000-4-5
Signal± 1 kV
Standards/regulationsEN 55011
Standards/regulationsEN 61000-4-6
Shock15g in all directions in acc. with IEC 60068-2-27
Vibration (operation)in acc. with IEC 60068-2-6: 5g, 150 Hz
Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU
Type of testVibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6
Test result5g, 10...150 Hz, 2.5 h, in XYZ direction
Type of testShock in acc. with EN 60068-2-27/IEC 60068-2-27
Test result15g, 11 ms period, half-sine shock pulse
Noise emissionEN 55011

Dimensions

Width35 mm
Height99 mm
Depth106 mm

Digital outputs

Output nameRelay output
Output descriptionAlarm output
Number of outputs1
Maximum switching voltage60 V DC
Maximum switching voltage42 V AC
Limiting continuous current0.46 A

Power supply

Nominal supply voltage24 V DC (With UL approval)
Supply voltage range18 V DC - 30 V DC
Max. current consumption130 mA
Typical current consumption120 mA (24 V DC)
Connection methodCOMBICON plug-in screw terminal block

Note

Utilization restrictionEMC: class A product, see manufacturer's declaration in the download area

Documentazione


Spesso acquistati assieme


Altri articoli da PHOENIX CONTACT

Richiedi un preventivo