E3S 2000 PR122/P-LI In=2000A 4p F HR
- Produttore:
- ABB
- Prezzo (IVA esclusa)
- € 21788.10
- Codice Nuova Elva
- 1SDA056251R1
- Codice produttore
- 1SDA056251R1
- Disponibilità
- Invia RdO
SACE EMAX CIRCUIT-BREAKER E3S 2000A FOUR-POLE FIXED WITH TERMINALS REAR HORIZONTAL OVERCURRENT RELEASE PR122/P-LI R2000 FITTED WITH: 4 AUXILIARY CONTACT AND C.BREAKER IN POSITION OPEN-CLOSED
Specifications
Ordering | |
---|---|
EAN | 8015644575915 |
Minimum Order Quantity | 1 piece |
Customs Tariff Number | 85362090 |
Dimensions | |
Product Net Width | 530 mm |
Product Net Height | 418 mm |
Product Net Depth / Length | 302 mm |
Product Net Weight | 76 kg |
Container Information | |
Package Level 1 Depth / Length | 785 mm |
Package Level 1 Gross Weight | 90 kg |
Package Level 1 EAN | 8015644575915 |
Package Level 1 Units | 1 piece |
Package Level 1 Width | 515 mm |
Package Level 1 Height | 600 mm |
Additional Information | |
Current Type | AC |
Electrical Durability | Ue =< 440 V 9000 cycleUe = 500 ... 690 V 9000 cycle20 cycles per hour |
Mechanical Durability | 20000 cycle60 cycles per hour |
Number of Poles | 4 |
Power Loss | 130 W |
Product Main Type | SACE Emax |
Product Name | Air Circuit Breaker |
Product Type | Air Circuit Breaker |
Rated Current (In) | 2000 A |
Rated Voltage (Ur) | 690 V |
Rated Impulse Withstand Voltage (Uimp) | 12 kV |
Rated Insulation Voltage (Ui) | 1000 V |
Rated Operational Current (Ie) | 2000 A |
Rated Operational Voltage | 690 V AC |
Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 75 kA(230 V AC) 75 kA(380 V AC) 75 kA(400 V AC) 75 kA(415 V AC) 75 kA(440 V AC) 75 kA(500 V AC) 75 kA(660 V AC) 75 kA(690 V AC) 75 kA |
Rated Short-time Withstand Current (Icw) | for 1 s 75 kAfor 3 s 65 kA |
Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 75 kA(230 V AC) 75 kA(380 V AC) 75 kA(400 V AC) 75 kA(415 V AC) 75 kA(440 V AC) 75 kA(500 V AC) 75 kA(660 V AC) 75 kA(690 V AC) 75 kA |
Rated Uninterrupted Current (Iu) | 2000 A |
Release Type | EL |
Standards | IEC |
Sub-type | E3 |
Terminal Connection Type | Fixed Circuit-BreakersRear flat Horizontal |
Version | F |
Classifications | |
ETIM 4 | EC000228 - Power circuit-breaker for trafo/generator/installation prot. |
ETIM 5 | EC000228 - Power circuit-breaker for trafo/generator/installation prot. |
ETIM 6 | EC000228 - Power circuit-breaker for trafo/generator/installation prot. |
ETIM 7 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
Object Classification Code | Q |
UNSPSC | 39120000 |
WEEE Category | 4. Large Equipment (Any External Dimension More Than 50 cm) |