This XCSTR Safety Limit Switch has a 30 mm stainless steel spindle, a double insulated plastic enclosure and 2 x Pg 11 cable gland entries. It has 1 normally open and 2 normally closed break-before-make (slow break) contacts. Its B10D reliability data is 5 000 000. Its IP67 degree of protection makes it ideal for heavy duty use in harsh conditions. It also complies with EN/ISO 14119, EN/IEC 60204-1, EN/IEC 60947-5-1, EN/IEC 60947-5-4, UL 508, CSA C22.2 No 14 standards. When associated and correctly connected to an appropriate safety control unit, it conforms to Category 4, performance level PL e, SIL 3 as described in EN/ISO 13849-1, EN/IEC 61508.

Specifications

CertificationsBG
Chain/Cable Diameter7-10 mm
Depth60 mm
Enclosure MaterialPolyamide PA66 Fibre Glass Impregnated
Height117-117 mm
MaterialPlastic
Net Weight0.155 kg
Number of Poles3
StandardCSA C22.2 No 14
Storage Temperature-40-70 °C
Warranty Length18 months
Width52 mm

Specifications

Contacts Type And Composition1 NC + 1 NC + 1 NO
Contact Operationslow-break, break before make
Type Of Operatorspindle 30 mm
Electrical Connectionterminal
Number Of Poles3
Range Of ProductTelemecanique Safety switches XCS
Cable Entry2 entries tapped Pg 11
Clamping Connection Capacity1 x 0.34...2 x 0.75 mm² with or without cable end
Product Or Component Typeguard switch
Component NameXCSTR
Materialplastic
Head Typeturret head rotary axis
Insulationdouble insulated

Contractual warranty

Warranty18 months

Complementary

Height117-117 mm
Positive Openingwith NC contact
Positive Opening Minimum Torque0.45 N.m
Mechanical Durability1000000 cycles
Safety Reliability DataB10d = 5000000 value given for a life time of 20 years limited by mechanical or contact wear
Enclosure Materialpolyamide PA66 fibre glass impregnated
Contact Code DesignationB300, AC-15 (Ue = 120 V, Ie = 6 A)EN/IEC 60947-5-1 || B300, AC-15 (Ue = 240 V, Ie = 3 A)EN/IEC 60947-5-1 || Q300, DC-13 (Ue = 125 V, Ie = 0.2 A)EN/IEC 60947-5-1 || R300, DC-13 (Ue = 250 V, Ie = 0.1 A)EN/IEC 60947-5-1
Width52 mm
Depth60 mm
Cable Outer Diameter7-10 mm
Minimum Torque For Tripping0.1 N.m
Short-Circuit Protection6 A cartridge fuse gG (gl)
Maximum Resistance Across Terminals30 mOhm EN/IEC 60947-5-4
Safety Levelcan reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 with the appropriate monitoring system and correctly wired IEC 61508
Minimum Actuation Speed0.1 m/s
[Ithe] Conventional Enclosed Thermal Current6 A
Lever Materialstainless steel
Tripping Angle5 °
Net Weight0.155 kg
[Uimp] Rated Impulse Withstand Voltage4 kV EN/IEC 60947-5-1
[Ui] Rated Insulation Voltage300 VUL 508 || 300 VCSA C22.2 No 14 || 400 V 3)EN/IEC 60947-1

Offer Sustainability

Rohs Exemption InformationYes
Mercury FreeYes
Environmental DisclosureENVPEP110606EN
Sustainable Offer StatusGreen Premium product
Reach RegulationReference contains Substances of Very High Concern above the threshold
California Proposition 65WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Circularity ProfileENVEOLI110603EN
Eu Rohs DirectivePro-active compliance (Product out of EU RoHS legal scope)

Environment

Product CertificationsUL || CSA || BG
Ambient Air Temperature For Operation-25-70 °C
StandardsEN/ISO 12100 || EN/IEC 60947-5-1 || EN/IEC 60204-1 || CSA C22.2 No 14 || EN 1088/ISO 14119 || EN/IEC 60947-5-4 || UL 508
Shock Resistance50 gn 11 ms IEC 60068-2-27
Vibration Resistance50 gn 10-500 Hz)IEC 60068-2-6
Ip Degree Of ProtectionIP67 conforming to IEC 60529
Ambient Air Temperature For Storage-40-70 °C
Electrical Shock Protection Classclass II EN/IEC 61140
Protective TreatmentTC || TH