Reversing contactor, TeSys K, 3P, AC-3, lt or eq to 440V 6A, 1 NO, 48VAC coil

Produttore:
Schneider Electric
Schneider%20electric

0697fd9e57659fc54f71e2c0d29acbf1c7979336 medium
Prezzo (IVA esclusa)
€ 92.52
Codice Nuova Elva
LC2K0610E7
Codice produttore
LC2K0610E7
Disponibilità
1 in stock

LC2K0610E7 is a compact 3-pole TeSys K reversing contactor from Schneider Electric for motor applications. Rated 6A AC-3 2.2kW@400V, it includes a 48V 50/60Hz AC coil, 2NO auxiliary contacts, a mechanical interlock and pre-wired reversing circuit. LC2K0610E7 is a 3-pole TeSys K reversing contactor from Schneider Electric for simple motor applications rated up to 2.2kW@400V. Very compact, DIN-rail compatible, with connections by screw clamp terminals, it is assembled with a mechanical interlock and a pre-wired reversing circuit. It includes a 48V 50/60Hz AC coil and 2NO built-in auxiliary contacts. Available worldwide, it complies with multi-standards (IEC, UL, CSA, CCC, EAC, Marine) and is certified Green Premium (RoHs/Reach). Very compact, 90mm wide, for DIN-rail and panel mounting. Assembled with mechanical interlock and pre-wired reversing circuit. Provides a 48V AC coil compatible 50/60Hz and 2NO built-in auxiliary contact. Can be completed with auxiliary contact blocks (LA1K, LA2K) and thermal relays (LR2K).

Specifications

CertificationsCB Scheme
Contact Configuration1 NO
Depth57 mm
Height58 mm
Impedance3 MOhm - Ith 20 A 50 Hz Power Circuit
Net Weight0.39 kg
StandardCSA C22.2 No 60947-4-1
Storage Temperature-50-80 °C
Warranty Length18 months
Width90 mm

Specifications

Product CertificationsCB Scheme || CCC || UL || CSA || EAC || CE || UKCA
Control Circuit TypeAC 50/60 Hz
Safety Reliability LevelB10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Contactor Applicationmotor control
Rated Breaking Capacity110 A 415 V IEC 60947 || 110 A 440 V IEC 60947 || 80 A 500 V IEC 60947 || 110 A 220...230 V IEC 60947 || 110 A 380...400 V IEC 60947 || 70 A 660...690 V IEC 60947
Product Or Component Typereversing contactor
Irms Rated Making Capacity110 A AC power circuit NF C 63-110 || 110 A AC power circuit IEC 60947 || 110 A AC signalling circuit IEC 60947
Product NameTeSys K
Associated Fuse Rating25 A gG <= 440 V power circuit || 25 A aM power circuit || 10 A gG signalling circuit IEC 60947 || 10 A gG signalling circuit VDE 0660
[Uimp] Rated Impulse Withstand Voltage8 kV
Connections - Terminalsscrew clamp terminals 1 1.5-4 mm²solid || screw clamp terminals 1 0.75-4 mm²flexible without cable end || screw clamp terminals 1 0.34-2.5 mm²flexible with cable end || screw clamp terminals 2 1.5-4 mm²solid || screw clamp terminals 2 0.75-4 mm²flexible without cable end || screw clamp terminals 2 0.34-1.5 mm²flexible with cable end
Interlocking Typemechanical
RangeTeSys
Pole Contact Composition3 NO
Device Presentationpreassembled with reversing power busbar
Utilisation CategoryAC-3 || AC-4 || AC-3e
[Ie] Rated Operational Current6 A<= 440 V AC AC-3 power circuit || 6 A<= 440 V AC AC-3e power circuit
Maximum Operating Rate3600 cyc/h
Electrical Durability1.3 Mcycles 6 A AC-3 <= 440 V || 1.3 Mcycles 6 A AC-3e <= 440 V
Mechanical Durability5 Mcycles
Poles Description3P
Operating Time10...20 ms coil energisation and NO closing || 10...20 ms coil de-energisation and NO opening
[Uc] Control Circuit Voltage48 V AC 50/60 Hz
Tightening Torque0.8-1.3 N.m screw clamp terminals Philips No 2 || 0.8-1.3 N.m screw clamp terminals flat Ø 6 mm || 0.8-1.3 N.m screw clamp terminals pozidriv No 2
Overvoltage CategoryIII
Motor Power Kw1.5 kW 220...230 V AC 50/60 Hz || 2.2 kW 380...415 V AC 50/60 Hz || 3 kW 440 V AC 50/60 Hz || 3 kW 480 V AC 50/60 Hz || 3 kW 500...600 V AC 50/60 Hz || 3 kW 660...690 V AC 50/60 Hz
[Ui] Rated Insulation Voltagepower circuit 600 V UL 508 || power circuit 690 V IEC 60947-4-1 || signalling circuit 690 V IEC 60947-4-1 || signalling circuit 690 V IEC 60947-5-1 || signalling circuit 600 V UL 508 || power circuit 600 V CSA C22.2 No 14 || signalling circuit 600 V CSA C22.2 No 14
Device Applicationcontrol
Device Short NameLC2K
[Icw] Rated Short-Time Withstand Current90 A 50 °C - 1 s power circuit || 85 A 50 °C - 5 s power circuit || 80 A 50 °C - 10 s power circuit || 60 A 50 °C - 30 s power circuit || 45 A 50 °C - 1 min power circuit || 40 A 50 °C - 3 min power circuit || 80 A - 1 s signalling circuit || 90 A - 500 ms signalling circuit || 110 A - 100 ms signalling circuit || 20 A 50 °C - >= 15 min power circuit
[Ue] Rated Operational Voltagepower circuit 690 V AC 50/60 Hz || signalling circuit <= 690 V AC 50/60 Hz
Average Impedance3 mOhm - Ith 20 A 50 Hz power circuit
Auxiliary Contact Composition1 NO
[Ith] Conventional Free Air Thermal Current20 A 50 °C power circuit || 10 A 50 °C signalling circuit
StandardsEN/IEC 60947-4-1 || GB/T 14048.4 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1
Mounting Supportrail || plate

Contractual warranty

Warranty18 months

Complementary

Minimum Switching Current5 mA signalling circuit
Heat Dissipation1.3-1.3 W
Control Circuit Voltage Limitsoperational 0.8...1.15 Uc 50 °C) || drop-out 0.2...0.75 Uc 50 °C)
Non Overlap Distance0.5 mm
Insulation Resistance> 10 MOhm signalling circuit
Inrush Power In Va30-30 VA 20 °C)
Minimum Switching Voltage17 V signalling circuit
Signalling Circuit Frequency<= 400 Hz
Auxiliary Contacts Typeinstantaneous 1 NO
Hold-In Power Consumption In Va4.5-4.5 VA 20 °C)

Offer Sustainability

Rohs Exemption InformationYes
China Rohs RegulationPro-active China RoHS declaration (out of China RoHS legal scope)
Circularity ProfileENVEOLI1503003EN
Eu Rohs DirectiveCompliant
Mercury FreeYes
Environmental DisclosureENVPEP1503003EN
Sustainable Offer StatusGreen Premium product
Toxic Heavy Metal FreeYes
Reach RegulationFree of Substances of Very High Concern above the threshold
California Proposition 65WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
Reach Free Of SvhcYes
WeeeThe product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.

Environment

Mechanical Robustnessshocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27 || shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27 || shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27 || shocks contactor opened, on X axis6 Gn for 11 ms IEC 60068-2-27 || shocks contactor opened, on Y axis10 Gn for 11 ms IEC 60068-2-27 || shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27 || vibrations contactor closed4 Gn, 5...300 Hz IEC 60068-2-6 || vibrations contactor opened2 Gn, 5...300 Hz IEC 60068-2-6
Width90 mm
Depth57 mm
Ambient Air Temperature For Operation-25-50 °C
Height58 mm
Net Weight0.39 kg
Flame RetardanceV1 conforming to UL 94 || requirement 2 conforming to NF F 16-101 || requirement 2 conforming to NF F 16-102
Ambient Air Temperature For Storage-50-80 °C
Protective TreatmentTC IEC 60068 || TC DIN 50016
Ip Degree Of ProtectionIP20 VDE 0106
Operating Altitude6561.68 ft (2000 m) without derating

Documentazione


Altri articoli da Schneider Electric

Richiedi un preventivo