Type 2 surge protection plug - VAL-MS 230 ST - 2798844

Produttore:
PHOENIX CONTACT
Phoenix%20contact

24c6c521b263abc3200a14d8937df91b09feec22 medium
Prezzo (IVA esclusa)
€ 76.85
Codice Nuova Elva
2798844
Codice produttore
2798844
Disponibilità
6 in stock

Surge protection connector type 2 with high-capacity varistor for VAL-MS base element, thermal monitoring, visual fault warning. Design: 230 V AC

Features

  • CCA

  • EAC

  • cULus Recognized

  • GL

  • IECEE CB Scheme

  • KEMA-KEUR

  • CSA

  • ÖVE

  • UL Recognized

  • cUL Recognized

Specifications

Depth55.3 mm
Height52.4 mm
Width17.5 mm

Environmental Product Compliance

China RoHSEnvironmentally Friendly Use Period = 50 years
China RoHSFor details about hazardous substances go to tab 'Downloads', Category 'Manufacturer's declaration'

Dimensions

Height52.4 mm
Width17.5 mm
Depth55.3 mm
Horizontal pitch1 Div.

UL specifications

SPD Type4CA
Maximum continuous operating voltage MCOV (L-N)275 V AC
Nom. voltage230 V AC
Mode of protectionL-N
Power distribution systemSingle phase
Nominal frequency50/60 Hz
Measured limiting voltage MLV (L-N)1910 V
Nominal discharge current In (L-N)20 kA

Connection data

Connection methodpluggable

Ambient conditions

Shock (operation)25g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
Vibration (operation)5g (10 - 500 Hz / 2.5 h / X, Y, Z)
Degree of protectionIP20
Ambient temperature (operation)-40 °C - 80 °C
Ambient temperature (storage/transport)-40 °C - 80 °C
Altitude≤ 2000 m (amsl (above mean sea level))
Permissible humidity (operation)5 % - 95 %

Protective circuit

Nominal voltage UN240/415 V AC (TN)
Nominal voltage UN240/415 V AC (TT)
Nominal frequency fN50 Hz (60 Hz)
Maximum continuous voltage UC275 V AC
Residual current IPE≤ 0.45 mA
Standby power consumption PC≤ 120 mVA
Nominal discharge current In (8/20) µs20 kA
Maximum discharge current Imax (8/20) µs40 kA
Short-circuit current rating ISCCR25 kA
Voltage protection level Up≤ 1.35 kV
Residual voltage Ures≤ 1.35 kV (at In)
Residual voltage Ures≤ 1.1 kV (at 10 kA)
Residual voltage Ures≤ 1 kV (at 5 kA)
Residual voltage Ures≤ 0.9 kV (at 3 kA)
TOV behavior at UT335 V AC (5 s / withstand mode)
TOV behavior at UT440 V AC (120 min / safe failure mode)
Response time tA≤ 25 ns
Max. backup fuse with branch wiring125 A (gG)

Standards and Regulations

Standards/regulationsIEC 61643-11 2011
Standards/regulationsEN 61643-11 2012

Documentazione


Spesso acquistati assieme


Altri articoli da PHOENIX CONTACT

Richiedi un preventivo