Power supply unit - TRIO-PS-2G/1AC/24DC/10 - 2903149

Manufactured by:
PHOENIX CONTACT
Phoenix%20contact

A30900e835f4096731ceaa6997c57c5e5826c7a9 medium
Price (VAT excluded)
€ 210.85
Nuova Elva code
2903149
Manufacturer code
2903149
Availability
6 in stock

Primary-switched TRIO POWER power supply with push-in connection for DIN rail mounting, input: single phase, output: 24 V DC/10 A

Features

  • Save time and costs, thanks to the Push-in connection and narrow design

  • Increase system availability, thanks to dynamic boost with 150% of the nominal current for five seconds

  • Maximum flexibility due to the wide temperature range from -25°C to +70°C and device startup at -40°C

  • Rugged design

  • cULus Listed

  • cULus Recognized

  • EAC

  • DNV GL

  • IECEE CB Scheme

  • UL Listed

  • cUL Listed

  • UL Recognized

  • cUL Recognized

Specifications

Depth160 mm
Height130 mm
Output Voltage24 V
Strip Length10 mm
Voltage10 V
Width42 mm

Environmental Product Compliance

REACh SVHCLead 7439-92-1
China RoHSEnvironmentally Friendly Use Period = 25;
China RoHSFor details about hazardous substances go to tab 'Downloads', Category 'Manufacturer's declaration'

Standards

EMC requirements for noise immunityEN 61000-6-1
EMC requirements for noise immunityEN 61000-6-2
EMC requirements for noise emissionEN 61000-6-3
EMC requirements for noise emissionEN 61000-6-4
Standard - Safety of transformersEN 61558-2-16 (air clearances and creepage distances only)
Standard - Electrical safetyIEC 60950-1/VDE 0805 (SELV)
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installationsEN 50178/VDE 0160 (PELV)
Standard – Safety extra-low voltageIEC 60950-1 (SELV) and EN 60204-1 (PELV)
Standard - Safe isolationDIN VDE 0100-410
Standard – Limitation of mains harmonic currentsEN 61000-3-2
Rail applicationsEN 50121-4

Dimensions

Width42 mm
Height130 mm
Depth160 mm
Installation distance right/left0 mm / 0 mm
Installation distance top/bottom50 mm / 50 mm

Output data

Nominal output voltage24 V DC ±1 %
Setting range of the output voltage (USet)24 V DC - 28 V DC (constant capacity)
Nominal output current (IN)10 A
Dynamic Boost (IDyn.Boost)15 A (5 s)
Derating> 60 °C - 70 °C (2.5%/K)
Connection in parallelYes, for redundancy and increased capacity
Connection in seriesyes
Feedback voltage resistance≤ 35 V DC
Protection against overvoltage at the output (OVP)≤ 30 V DC
Control deviation< 1 % (change in load, static 10 % - 90 %)
Control deviation< 3 % (Dynamic load change 10 % - 90 %, 10 Hz)
Control deviation< 0.1 % (change in input voltage ±10 %)
Residual ripple< 10 mVPP (with nominal values)
Output power240 W
Typical response time< 1 s
Maximum power dissipation in no-load condition< 5.1 W (230 V)
Power loss nominal load max.< 25 W

EMC data

Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU
Low Voltage DirectiveConformance with Low Voltage Directive 2014/35/EC
Electrostatic dischargeEN 61000-4-2
Contact discharge6 kV (Test Level 4)
Discharge in air8 kV (Test Level 4)
Electromagnetic HF fieldEN 61000-4-3
Frequency range80 MHz - 1 GHz
Frequency range1 GHz - 2 GHz
Test field strength10 V/m (Test Level 3)
Frequency range2 GHz - 3 GHz
CommentsCriterion A
Fast transients (burst)EN 61000-4-4
Input4 kV (Test Level 4 - asymmetrical)
Output2 kV (Test Level 3 - asymmetrical)
Signal1 kV (Test Level 2 - asymmetrical)
Surge voltage load (surge)EN 61000-4-5
Input3 kV (Test Level 3 - symmetrical)
Input6 kV (Test Level 4 - asymmetrical)
Output1 kV (Test Level 2 - symmetrical)
Output2 kV (Test Level 1 - asymmetrical)
CommentsCriterion B
Conducted interferenceEN 61000-4-6
Frequency range0.15 MHz - 80 MHz
Voltage10 V (Test Level 3)
Criterion ANormal operating behavior within the specified limits.
Criterion BTemporary impairment to operational behavior that is corrected by the device itself.

Input data

Nominal input voltage range100 V AC - 240 V AC
Nominal input voltage range110 V DC - 250 V DC
Input voltage range100 V AC - 240 V AC -15 % - +10 %
Input voltage range110 V DC - 250 V DC -10 % - +10 %
Dielectric strength maximum300 V AC 15 s
AC frequency range50 Hz - 60 Hz ±10 %
Discharge current to PE< 3.5 mA
Current consumption3.1 A (100 V AC)
Current consumption2.4 A (120 V AC)
Current consumption1.3 A (230 V AC)
Current consumption1.4 A (240 V AC)
Nominal power consumption285 VA
Inrush current≤ 25 A (typical)
Mains buffering timetyp. 15 ms (120 V AC)
Mains buffering timetyp. 20 ms (230 V AC)
Input fuse6.3 A (internal (device protection))
Recommended breaker for input protection6 A - 16 A (Characteristics B, C, D, K)
Power factor (cos phi)0.93
Type of protectionTransient surge protection
Protective circuit/componentVaristor

Ambient conditions

Ambient temperature (storage/transport)-40 °C - 85 °C
Max. permissible relative humidity (operation)≤ 95 % (at 25 °C, non-condensing)
Climatic class3K3 (in acc. with EN 60721)
Degree of pollution2
Installation height≤ 5000 m (> 2000 m, Derating: 10 %/1000 m)
Degree of protectionIP20
Inflammability class in acc. with UL 94 (housing / terminal blocks)V0
Ambient temperature (operation)-25 °C - 70 °C (> 60 °C Derating: 2.5 %/K)
Ambient temperature (start-up type tested)-40 °C

Connection data, input

Connection methodPush-in connection
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.4 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.12
Stripping length10 mm

Connection data, output

Connection methodPush-in connection
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.4 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.12
Stripping length8 mm

Conformance/approvals

UL approvalsUL Listed UL 508
UL approvalsUL/C-UL Recognized UL 60950-1

Connection data for signaling

Connection methodPush-in connection
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.1.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.1.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.16
Stripping length8 mm

Frequently bought together


Other PHOENIX CONTACT items

Request a quote