Type: |
PNOZ 2VJ |
Product version: |
5.1 |
Approvals: |
UL/cUL, EC, TÜV, CCC |
Category in accordance with: |
EN 954-1, EN ISO 13849-1 |
Application options: |
Safety gate monitors, Instantaneous E-STOP monitorin, Limit switch, Delayed E-STOP monitoring |
Operating modes: |
single-channel, Automatic reset, Dual-channel, Manual reset, without detection of shorts ac |
PL EN ISO 13849-1 inst. contacts: |
e |
PL EN ISO 13849-1 del. contacts <30s: |
d |
SIL CL IEC 62061 inst. contacts: |
3 |
SIL CL IEC 62061 del. contacts <30s: |
3 |
Product standard: |
EN 60947-5-1 |
Standards: |
EN 60204-1, EN 62061, EN 954-1, VDE 0113-1 |
Supply voltage: |
-24 V |
Supply voltage type: |
DC |
Terminal style: |
fixed |
Terminal type: |
Screw terminal |
Cat. inst. saf. contacts: |
4 |
Number of instantaneous safety contacts: |
3 |
Number of delayed safety contacts: |
2 |
Number of auxiliary contacts: |
1 |
Selectable times: |
0,10 s, 0,20 s, 0,30 s, 0,40 s, 0,50 s, 0,60 s, 0,70 s, 0,80 s, 1,00 s, 1,50 s, 2,00 s, 3,00 s |
Stop category: |
0/1 |
Max. current at DC13 I (6 cycles/min): |
7.0 A |
Max. current at AC15: |
5.0 A |
Width dimension: |
112.5 mm |
Height dimension: |
87.0 mm |
Depth dimension: |
121.0 mm |
Gross weight: |
614 g |
Net weight: |
597 g |
Ambient temperature: |
-10 - 55 °C |